Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Winfield, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Winfield, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Winfield, IL

Get Your Quote Today

Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Michelle, S. Winfield, IL
11-02-2021

Jeremiah , H. Winfield , IL
01-13-2023
Upon Arrival Pre Clean Up Start-up Operations Are Good. The Interior Of The Furnace Was A Bit Dirty. Cleaned Up The Interior Of The Furnace, Flame Sensor, Burner Assembly & Motors Housing. Post-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. Air Filter Is Still Good.
Karen, S. Winfield, IL
11-02-2021
FReport Furnace Report: Furnace Report • Inducer - .2 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation MP HUM Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Luke , S. Winfield , IL
09-21-2021
Upon Arrival. Outdoor AC Equipment Fan Motor Was A Bit High On Amps, After Clean Up The Amps Went Down. Furnace Motors Are Working Properly, Nice Blue Flame Indicating Proper Burn. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter ACPM Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 154 Low Pressure - 59 Ambient Temp - 79 Delta T Reading -17 Contactor Resistance Reading -17.4 Low Voltage Wiring Check Capacitor Reading 40/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor -8 Amp Draw On Condenser Fan -1.1 Check Filter/Replace Clean Drain Test Blower Motor
Martin , D. Winfield , IL
09-21-2021
Due To The Age Of The Unit I Feel A New System Would Be A Better Fit. We Offer Some Great Financing Options Annual Furnace Preventative Maintenance: Furnace Report Manufacturer Date 2006 • Inducer MNF/1.75 Test/1.7 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger - Heavy Signs Rust • Check Ignitor • Check/replace Filter • Check Drain • Inspect Intake For Debris • Test Gas Shut Off • Test Thermostat For Proper Operation • Blower Capacitor Inducer Bearings Failing Inducer Running High Amps
Jeff, I. Winfield , IL
09-21-2021
Furnace Report • Inducer Amps MNF/ - Test/0.4A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners. No Obstructions • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines No Blockages They Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Cracks Very Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues 1.00
Brad , G. Winfield , IL
10-15-2022

Brian's Heatingstarstarstarstarstar4.5 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

50 Total Reviews /files//brians-logo.png630-509-8310$847 Weyrauch St. , West Chicago IL