Hard Start Device 1.5-3 Ton
The 5-2-1 Compressor Saver® Protects These Components By Significantly Reducing The Amount Of Time It Takes For Your Compressor To Start – In Some Cases Up To 50%. This Means Your Air Conditioner And Compressor Will Bear – The Stress, Strain And Heat Each And Every Time It Starts. Considering That Your Air Conditioner May Start Up More Than 6,000 Times In A Single Cooling Season, The Positive Impact That The 5-2-1 Compressor Saver Has On Your Air Conditioner Is Significant.
A/C Report:
A/C Report 1St Floor
Clean And Check Outdoor Condenser
High Pressure - 225
Low Pressure - 112
Ambient Temp - 70
Delta T Reading -18
Contactor Resistance Reading -no Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 40/5@ 40.23 4.43
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -15.3@ 7.6
Amp Draw On Condenser Fan -1.1@ .68
Lock Rotor Amps - 83@ 91.6
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
A/C Report:
A/C Report 2nd Floor R22
Clean And Check Outdoor Condenser
High Pressure - 150
Low Pressure - 65
Ambient Temp - 70
Delta T Reading -
Contactor Resistance Reading - Replaced Contactor
Low Voltage Wiring Check No Issues
Capacitor Reading 45/5@ 45.5/4.8
Clean Out Electrical Compartment Cleaned
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor
[email protected]
Amp Draw On Condenser Fan
[email protected]
Lock Rotor Amps - 73@84 Recommended Hard Start Kit
Check Filter/Replace Replaced Air Filter
Clean Drain No Issues
Test Blower Motor No Issues
Jaime , P. Winfield , IL06-11-2022