is one of the leading providers of air conditioning repair and air conditioning service in Winfield, IL, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.
You'll find we take our job seriously and highly value the trust that is placed in us. goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Winfield, IL.
Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.
Aaron , L. Winfield , IL
06-11-2022
Hard Start Device 1.5-3 Ton
The 5-2-1 Compressor Saver® Protects These Components By Significantly Reducing The Amount Of Time It Takes For Your Compressor To Start – In Some Cases Up To 50%. This Means Your Air Conditioner And Compressor Will Bear – The Stress, Strain And Heat Each And Every Time It Starts. Considering That Your Air Conditioner May Start Up More Than 6,000 Times In A Single Cooling Season, The Positive Impact That The 5-2-1 Compressor Saver Has On Your Air Conditioner Is Significant.
A/C Report:
A/C Report 1St Floor
Clean And Check Outdoor Condenser
High Pressure - 225
Low Pressure - 112
Ambient Temp - 70
Delta T Reading -18
Contactor Resistance Reading -no Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 40/5@ 40.23 4.43
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -15.3@ 7.6
Amp Draw On Condenser Fan -1.1@ .68
Lock Rotor Amps - 83@ 91.6
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
A/C Report:
A/C Report 2nd Floor R22
Clean And Check Outdoor Condenser
High Pressure - 150
Low Pressure - 65
Ambient Temp - 70
Delta T Reading -
Contactor Resistance Reading - Replaced Contactor
Low Voltage Wiring Check No Issues
Capacitor Reading 45/5@ 45.5/4.8
Clean Out Electrical Compartment Cleaned
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor
[email protected]
Amp Draw On Condenser Fan
[email protected]
Lock Rotor Amps -
[email protected] Recommended Hard Start Kit
Check Filter/Replace Replaced Air Filter
Clean Drain No Issues
Test Blower Motor No Issues
Jaime , P. Winfield , IL06-11-2022
Replaced Contactor And Capacitor Ac Up And Running Refrigerant Levels Up To Part
Wes , M. Winfield, IL
04-29-2022
1 LB Refrigerant Difluoromethane, Pentafluoro Ethane:
Furnish And Install 1 LB R-410A Refrigerant.
John , G. Winfield , IL
04-23-2022
Ducane 2HP13L42P-1AResidential Diagnosis Fee
Needs New Blower Wheel And Motor
Donna, B. Winfield, IL09-01-2020
Diagnosis
Upon Inspection Discovered Compressor Not Running Test Capacitor Manf Reading 35 Herm Terminal Reading 13.3 Recommend Replacement
1
35/5 MF Capacitor
Install 1 New Start / Run Capacitor
Andrew, H. Winfield, IL
07-31-2020
A/C Not Cooling, Repaired Capacitor And Checked For Proper Operation.
Jamie, H. Winfield , IL
09-04-2019
A/C Unit Was Not Working On Arrival. Found Drain Pan Was Filled With Water. Repaired Damaged Low Voltage Wiring Outside At Condenser.
Anthony, P. Winfield, IL
07-30-2019
No Cooling On Arrival. Replaced Blown 45/5 Capacitor With A New Dual 45/5 Capacitor.
Marissa, W. Winfield, IL
07-30-2019
"No Cooling" On Arrival. Found A Faulty Capacitor And A Blown Fuse. Tested Refrigerant Levels And Replaced Capacitor And Fuse. Restored Cooling Capabilities.
Jan, R. Winfield, IL
06-25-2019
Annual Cleaning And Inspection Of Air Conditioner
Joe, P. Winfield, IL
06-14-2019
Annual Air Conditioner Clean And Inspection For 2 Units
Bill, K. Winfield, IL
06-14-2019
Leaking Condenser - Added 3 Lbs Of 410-a And Injected Leak Stop.
Eric, B. Winfield, IL
06-05-2019
Annual Cleaning And Inspection Of Air Conditioner
Ron, H. Winfield, IL
04-26-2019
Repaired Low And High Voltage Wiring Due To Mouse Damage.
James, B. Winfield, IL
04-22-2019
No Cooling On Air Conditioner. Installed New Honeywell Pro 3000 Thermostat. Added 2lbs Of R-22
Brian, D. Winfield, IL
04-17-2019
Replaced "blown" Capacitor
Kathy, A. Winfield, IL
03-22-2019