Gas Furnace Maintenance
Are you looking for gas furnace maintenance in Wheaton, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Wheaton, IL
Justin , R. Wheaton , IL
12-09-2022
Furnace Report
• Inducer Amps MNF/1.2 - Test/.7
• Clean Flame Sensor Yes
• Blower Motor Capacitor MNF/ 5mfd- Test/4.9
• Inspect Wiring Yes
• Inspect Burner Yes
• Inspect Orifices For Blockage Yes
• Carbon Monoxide Test Yes
• Inspect Chimney Leaking
• Inspect Pressure Switch Lines Yes
• Test Sequence Of Operation Yes
• Inspect Heat Exchanger Yes
• Check Ignitor 50.2 Ohms
• Check/replace The Filter Clean Did Not Replaced
• Test Gas Shut Off Yes
• Test Thermostat For Proper Operation Yes
Joan , C. Wheaton , IL
10-28-2022
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Grace , V. Wheaton, IL
11-03-2021
Vent Working Working In Great Amp Range And So Is The Blower Motor. Furnace Is Kept Well Clean. Would Recommend Replacing Part Of The Vent Pipe Due To Rust & Hole In It
FPM Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Andrea , L. Wheaton, IL
09-29-2021
Furnace Report:
• Inducer Mmf/.35 @ .14
• Clean Flame Sensor Cleaned
• Inspect Blower Motor No Issues
• Inspect Wiring Everything Looks Good
• Inspect Burner No Issues
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor Checked Amps And Ohms
• Check/replace Filter Is Clean
• Test Gas Shut Off Is Good
• Test Thermostat For Proper Operation No Issues
Bill, N. Wheaton, IL
12-09-2021
William , B. Wheaton , IL
12-09-2022
Furnace Report
• Inducer Amps MNF/ - Test/ 0.6A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/ N/A Relay
• Inspect Wiring Wiring Is All Good No Issues
• Inspect Burner Burners Are Good No Blockages
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Correctly No Issues
• Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Blockages
• Test Sequence Of Operation Sequence Of Operations Is Good
• Inspect Heat Exchanger Heat Exchanger Is Good No Issues
• Check Ignitor Ignitor Is Good
• Check/replace The Filter Replaced Filter
• Test Gas Shut Off Gas Shut Off Works No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Steven , W. Wheaton , IL
09-23-2022
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Is Still Good, Recommended To Change It In About 3 Weeks.
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Judy , V. Wheaton , IL
10-20-2021