Are you looking for gas furnace maintenance in Wheaton, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Wheaton, IL

Get Your Quote Today

*2 Furnaces* Upon Arrival, Pre-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. The Flame Sensor Was Pretty Dirty In Both Furnaces. The Switches Are Good. Cleaned Up Flame Sensor, Motors Housing, Burner Assembly, Interior Of Furnaces. Both Air Filters Are In Ok Condition. Offered Humidifier Maintenance & The Homeowner Declined. Both Furnaces Were Manufactured In April 2013. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Larissa, B. Wheaton , IL
10-15-2021
Furnace Report • Inducer Amps MNF/ - Test/ 0.6A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring Wiring Is All Good No Issues • Inspect Burner Burners Are Good No Blockages • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Correctly No Issues • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Blockages • Test Sequence Of Operation Sequence Of Operations Is Good • Inspect Heat Exchanger Heat Exchanger Is Good No Issues • Check Ignitor Ignitor Is Good • Check/replace The Filter Replaced Filter • Test Gas Shut Off Gas Shut Off Works No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Steven , W. Wheaton , IL
09-23-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Mike , K. Wheaton, IL
12-20-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Is Still Good, Recommended To Change It In About 3 Weeks. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Judy , V. Wheaton , IL
10-20-2021
For Boiler Maintenance We Clean Out The Strainer For The Fill Valve After That We Took Burners Apart And Cleaned Them With A Brush We Also Inspected The Expansion Tank And Check The Air Vents For Any Leaks Or Possibilities Of Leaks After That Checked The Circulating Pump To Ensure That's Its Working And After We Cycled The Unit In Heating To Ensure Both Water Supply And Return Are Hot Systems Is Running As Designed.
Joe, B. Wheaton , IL
11-03-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust Or Issues • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0 Ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor NA • Check/replace Filter FILTER Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
William, B. Wheaton, IL
12-14-2021
Both Furnaces Are In Great Working Condition, Both Were Really Dirty Inside. Cleaned Up Motors & Safety Sensor.
David , T. Wheaton , IL
09-20-2021
1st-floor Furnace - Pre-clean-up Start-up Operations Are Good. Vent Motor Bearings Are Going Bad, Loud Noise Coming From The Vent Motor, Operating Amps Are Running A Bit High, The Interior Of Furnace Pretty Rusted. Cleaned Up Motors Housing, Flame Sensor, Burner Assembly, The Interior Of The Furnace. Post-clean-up Start-up Operations Are Good But The Vent Motor Is Still Operating In High Amps. Furnace Manufactured In October 1994. 2nd-floor Furnace- Pre-clean-up Start-up Operations Are Good. The Interior Of The Furnace Was A Bit Dirty. Cleaned Up The Interior Of The Furnace, Flame Sensor, Burner Assembly & Motors Housing. Post-clean-up Start-up Operations Are Good. Motors Are Working Well Within Amp Rate. Air Filters Look Good In Both Furnaces Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
David , D. Wheaton, IL
11-02-2021
Furnace Report • Inducer Amps MNF/2.35 - Test/ • Clean Flame Sensor- Yes • Blower Motor Capacitor MNF/5mfd - Test/4.9mfd • Inspect Wiring-yes • Inspect Burner-yes • Inspect Orifices For Blockage-yes • Carbon Monoxide Test-no • Inspect Chimney Yes • Inspect Pressure Switch Lines- Yes • Test Sequence Of Operation-yes • Inspect Heat Exchanger No • Check Ignitor Yes 49.9 Ohms • Check/replace The Filter- Yes • Test Gas Shut Off- Yes • Test Thermostat For Proper Operation- Yes Furnace Report • Inducer Amps MNF/1.0 - Test/1.03 • Clean Flame Sensor Yes • Blower Motor Capacitor MNF/5mfd - Test/4.7mfd • Inspect Wiring Yes • Inspect Burner Yes • Inspect Orifices For Blockage Yes • Carbon Monoxide Test No • Inspect Chimney Yes • Inspect Pressure Switch Lines Yes • Test Sequence Of Operation Yes • Inspect Heat Exchanger No • Check Ignitor Yes 82.57 Ohms • Check/replace The Filter Yes • Test Gas Shut Off Yes • Test Thermostat For Proper Operation Yes
Tom, L. Wheaton , IL
11-03-2022
Furnace Report: • Inducer Mmf/.35 @ .14 • Clean Flame Sensor Cleaned • Inspect Blower Motor No Issues • Inspect Wiring Everything Looks Good • Inspect Burner No Issues • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor Checked Amps And Ohms • Check/replace Filter Is Clean • Test Gas Shut Off Is Good • Test Thermostat For Proper Operation No Issues
Bill, N. Wheaton, IL
12-09-2021
Upon Arrival Customer Explained Unit Was Freezing Up. I Turned The Unit On To Verify Blower Operation, Discovered Blower On First And Second Failed. Recommend Replacement Of Both Blower Motor Recommend Replacement Of Filters To Prevent Future Failure 20x25x4 Box Filter Upon Arrival Customer Explained Unit Was Freezing Up. I Turned The Unit On To Verify Blower Operation, Discovered Blower On First And Second Failed. Recommend Replacement Of Both Blower Motor Recommend Replacement Of Filters To Prevent Future Failure 20x25x4 Box Filter Upon Arrival Customer Explained Unit Was Freezing Up. I Turned The Unit On To Verify Blower Operation, Discovered Blower On First And Second Failed. Recommend Replacement Of Both Blower Motor Removal Of Existing Motor And Install New Permanent Split Capacitor Rescue Motor.
Drew, T. Wheaton, IL
10-07-2021