Gas Furnace Maintenance
Are you looking for gas furnace maintenance in Wheaton, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Wheaton, IL
Furnace Report
• Inducer Amps MNF/2.35 - Test/
• Clean Flame Sensor- Yes
• Blower Motor Capacitor MNF/5mfd - Test/4.9mfd
• Inspect Wiring-yes
• Inspect Burner-yes
• Inspect Orifices For Blockage-yes
• Carbon Monoxide Test-no
• Inspect Chimney Yes
• Inspect Pressure Switch Lines- Yes
• Test Sequence Of Operation-yes
• Inspect Heat Exchanger No
• Check Ignitor Yes 49.9 Ohms
• Check/replace The Filter- Yes
• Test Gas Shut Off- Yes
• Test Thermostat For Proper Operation- Yes
Furnace Report
• Inducer Amps MNF/1.0 - Test/1.03
• Clean Flame Sensor Yes
• Blower Motor Capacitor MNF/5mfd - Test/4.7mfd
• Inspect Wiring Yes
• Inspect Burner Yes
• Inspect Orifices For Blockage Yes
• Carbon Monoxide Test No
• Inspect Chimney Yes
• Inspect Pressure Switch Lines Yes
• Test Sequence Of Operation Yes
• Inspect Heat Exchanger No
• Check Ignitor Yes 82.57 Ohms
• Check/replace The Filter Yes
• Test Gas Shut Off Yes
• Test Thermostat For Proper Operation Yes
Tom, L. Wheaton , IL
11-03-2022
Furnace Motors All Working Well . Cleaned Up Motors & Flame Sensor
Joe , S. Wheaton , IL
09-21-2021
Furnace Report:
Furnace Report
• Inducer ( Needs To Be Replaced)
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Yannick , K. Wheaton, IL
12-06-2021
Furnace Report:
Furnace Report
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor Dirty
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Air Filter Looks Good
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Karen, S. Wheaton, IL
01-18-2022
Justin , R. Wheaton , IL
12-09-2022
Furnace Report
• Inducer Amps MNF/ - Test/0.5A
• Clean Flame Sensor Cleaned Flame Sensor
• Blower Motor Capacitor MNF/ - Test/ N/A Relay
• Inspect Wiring All Wiring Is Good
• Inspect Burner Cleaned And Cleared Burners
• Inspect Orifices For Blockage No Blockages
• Carbon Monoxide Test No Issues
• Inspect Chimney Chimney Is Venting Properly
• Inspect Pressure Switch Lines Cleared Pressure Switch Lines
• Test Sequence Of Operation Sequence Of Operations Is Good And In Order
• Inspect Heat Exchanger No Issues. Clean Flame
• Check Ignitor Ignitor Is All Good
• Check/replace The Filter Filter Is Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
David , E. Wheaton , IL
10-29-2022
Furnace Report
• Inducer Amps MNF/1.2 - Test/.7
• Clean Flame Sensor Yes
• Blower Motor Capacitor MNF/ 5mfd- Test/4.9
• Inspect Wiring Yes
• Inspect Burner Yes
• Inspect Orifices For Blockage Yes
• Carbon Monoxide Test Yes
• Inspect Chimney Leaking
• Inspect Pressure Switch Lines Yes
• Test Sequence Of Operation Yes
• Inspect Heat Exchanger Yes
• Check Ignitor 50.2 Ohms
• Check/replace The Filter Clean Did Not Replaced
• Test Gas Shut Off Yes
• Test Thermostat For Proper Operation Yes
Joan , C. Wheaton , IL
10-28-2022
Both Furnaces Are In Great Working Condition, Both Were Really Dirty Inside. Cleaned Up Motors & Safety Sensor.