If your gas furnace in Wheaton, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Wheaton, IL

We provide gas furnace repair in Wheaton, IL

Get Your Quote Today

Service Call For Leaking Furnace. Installed New Condensate Pump For Customer And Checked The Unit For Proper Function.
Pamela , K. Wheaton, IL
09-04-2019
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 190 Low Pressure - 108 Ambient Temp - 45 Delta T Reading -21 Contactor Resistance Reading -3.0 Low Voltage Wiring Check No Issues Capacitor Reading 45/5 Clean Out Electrical Compartment Cleaned Out Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -15.4 @ 7.21 Amp Draw On Condenser Fan - 1.4 @.73 LRA- 83 @ 98.4 Recommended Hard Start Kit Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Mary , E. Wheaton , IL
04-29-2022
Found Rollout Switch Shorting Out Causing Fuse To Blow On Circuit Board Replaced Rollout And Tested Let Furnace Run For About 20 Min Cycled On And Off No Other Issues Found.
Patricia , M. Wheaton, IL
03-25-2022
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Service: Boiler Maintenance Test Exhaust Damper Verify Burner Operation Check Pressure Test Gas Shut Off Verify Water Valve Verify Pilot Test 24v Gas Valve Clean Burner Furnace Report 2nd Floor • Inducer Amps MNF/3.7 - Test/2.28 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
H.E , S. Wheaton, IL
10-29-2021
Furnace Report: Furnace Report 1st Floor • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Joe , V. Wheaton, IL
12-14-2021
Furnace Report • Inducer Amps MNF 2.8 - Test 2.26 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Darrell , D. Wheaton , IL
12-01-2021
Custom: Clean Inducer Office
Grace , V. Wheaton, IL