Are you looking for Air Conditioning maintenance in Wheaton, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Wheaton, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.

We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.

We provide Air Conditioning Maintenance in Wheaton, IL

We provide Air Conditioning Maintenance Agreements in Wheaton, IL

Get Your Quote Today

A/C Report Clean And Check Outdoor Condenser High Pressure - 310 Low Pressure - 125 Ambient Temp - 82 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check Capacitor Reading 45/[email protected]/5.1 Clean Out Electrical Compartment Cleaned Refrigeration Line Check - Low Side Insulation Service Valve Cap Caps Are In Place Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps -77.0@ 64.5 Check Filter/Replace Filter Is Clean Clean Drain No Issues Test Blower Motor No Issues
Spencer , J. Wheaton , IL
08-06-2022
Furnace Report • Inducer Amps MNF/1.45 - Test/1.27 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/5 - Test/4.9 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues A/C Report: A/C Report R22 Clean And Check Outdoor Condenser High Pressure - Low Pressure - Ambient Temp - 72 Delta T Reading - Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/5@32/4.7 Recommended Replacing Cap Clean Out Electrical Compartment Cleaned Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Hard Start Already Installed Check Filter/Replace Clean Drain Test Blower Motor
Jacob , J. Wheaton , IL
06-11-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 225 Low Pressure - 112 Ambient Temp - 70 Delta T Reading -18 Contactor Resistance Reading -no Issues Low Voltage Wiring Check No Issues Capacitor Reading 40/5@ 40.50/5.20 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -14.1@ 5.74 Amp Draw On Condenser Fan -0.8@ 0.7 Lock Rotor Amps - 73@ 82.6 Down To 64.5 Check Filter/Replace Replaced Air Filter Clean Drain No Issues Test Blower Motor No Issues
Dan , C. Wheaton , IL
06-11-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - Low Pressure - Ambient Temp - 70 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 50/5@ 35/5@ 50.1 4.99 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -15.3@ 9.4 Amp Draw On Condenser Fan -.80@ .64 Lock Rotor Amps - 86.0@ 103.6 Recommended Hard Start Kit 45 Check Filter/Replace Filter Look Good Clean Drain No Issues Test Blower Motor No Issues Hard Start Device 1.5-3 Ton The 5-2-1 Compressor Saver® Protects These Components By Significantly Reducing The Amount Of Time It Takes For Your Compressor To Start – In Some Cases Up To 50%. This Means Your Air Conditioner And Compressor Will Bear – The Stress, Strain And Heat Each And Every Time It Starts. Considering That Your Air Conditioner May Start Up More Than 6,000 Times In A Single Cooling Season, The Positive Impact That The 5-2-1 Compressor Saver Has On Your Air Conditioner Is Significant.
Joe, B. Wheaton, IL
06-11-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 215 Low Pressure - 131 Ambient Temp - 62 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 30/[email protected]/4.8 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Joe , S. Wheaton , IL
06-10-2022
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 215 Low Pressure - 131 Ambient Temp - 62 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 30/[email protected]/4.8 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Joe , S. Wheaton , IL
06-09-2022
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 230 Low Pressure - 125 Ambient Temp - 67 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 45/[email protected]/5.01 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Mike , K. Wheaton, IL
06-09-2022
A/C Report: A/C Report Left Side R22 Added 2 Lbs Clean And Check Outdoor Condenser High Pressure - 165 Low Pressure - 65 Ambient Temp - 64 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 45/[email protected]/4.37 Recommended Replacing Cap Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -20.4@ Amp Draw On Condenser Fan -1.1@ Lock Rotor Amps - 102@121 Check Filter/Replace Replaced Air Filter Clean Drain No Issues Test Blower Motor No Issues A/C Report: A/C Report Right Side R22 Clean And Check Outdoor Condenser High Pressure - 170 Low Pressure - 65 Ambient Temp - 64 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/5@ Clean Out Electrical Compartment Cleaned Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Joan , O. Wheaton , IL
06-03-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 310 Low Pressure - 126 Ambient Temp - 77 Delta T Reading - 18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check - No Issues Capacitor Reading - 35/5 @ 34.65/3.834 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap - No Issues Amp Draw On Compressor - 13.4 @ 6.03 Amp Draw On Condenser Fan - .70 @ 0.54 Lock Rotor Amps - 53 @ 56.6 Check Filter/Replace Air Filter Looks Good Clean Drain Repaired Drain Line Test Blower Motor No Issues
Patricia , M. Wheaton, IL
06-03-2022
A/C Report 1st Floor R22 Clean And Check Outdoor Condenser High Pressure - 175 Low Pressure - 55 Ambient Temp - 67 Delta T Reading -17 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 40/[email protected]/4.1 Recommended Replacing Cap Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues A/C Report 2nd Floor Low On R22 Clean And Check Outdoor Condenser High Pressure - 110 Low Pressure - 30 Ambient Temp - 69 Delta T Reading -7 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/[email protected]/4.44 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -8.44 Amp Draw On Condenser Fan -.56 Lock Rotor Amps - 77.1 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Rob , K. Wheaton , IL
05-26-2022
/C Report Clean And Check Outdoor Condenser High Pressure - 260 Low Pressure - 121 Ambient Temp - 68 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 50/[email protected]/5.06 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter Replaced Air Filter Clean Drain No Issues Test Blower Motor No Issues
Ann, K. Wheaton , IL
05-26-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 195 Low Pressure - 115 Ambient Temp - 55 Delta T Reading -17 Contactor Resistance Reading -4.1 Low Voltage Wiring Check No Issues Capacitor Reading 45/10 @ Clean Out Electrical Compartment Cleaned Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor - 17.9 @7.67 Amp Draw On Condenser Fan - 1.7 @1.2 Lock Rotor Amps - 113 @110.1 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Julie, H. Wheaton, IL
05-03-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 205 Low Pressure - 115 Ambient Temp - 50 Delta T Reading -18 Contactor Resistance Reading - 5.1 Low Voltage Wiring Check No Issues Capacitor Reading 40/5 @ 39.94/5.01 Clean Out Electrical Compartment Cleaned Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -12.8 @ 5.18 Amp Draw On Condenser Fan -.60 @.49 Lock Rotor Amps - 67.8 @73.6 Recommended Hard Start Kit 52.6 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Aaron , T. Wheaton , IL
05-03-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 160 Low Pressure - 61 Ambient Temp - 60 Delta T Reading - 16 Contactor Resistance Reading -3.4 Low Voltage Wiring Check No Issues Capacitor Reading 40/5 @ 35/5 Cleaned /coil Clean Out Electrical Compartment Cleared Out Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor - 14.7 @ 7.87 Amp Draw On Condenser Fan -1.3 @ .72 LRA-73 @ 88 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Wes , M. Wheaton, IL
04-23-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 220 Low Pressure - 112 Ambient Temp - 68 Delta T Reading - 19 Contactor Resistance Reading - 4.1 Low Voltage Wiring Check No Issues Capacitor Reading 45/7.5 @ 12.5/7.3 Recommended Replacing Clean Out Electrical Compartment Cleaned Off Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor - 21.2 @8.37 Amp Draw On Condenser Fan - 1.3 @.91 LRA 96 @ 102.3 Check Filter/Replace Replaced Air Filter Really Dirty Clean Drain No Issues Test Blower Motor No Issues
Allie, W. Wheaton, IL
04-12-2022
Custom: Mitsubishi Clean & Check Clean Indoor Coils Clean Drains Wash Filters Clean Outdoor Coils Mitsubishi Clean & Check Clean Indoor Coils Clean Drains Wash Filters Clean Outdoor Coils
Tammy , W. Wheaton, IL
07-01-2021
Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 260 Low Pressure - 110 Ambient Temp - 75 Delta T Reading - Contactor Resistance Reading - 19.8 Low Voltage Wiring Check Capacitor Reading - 35/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 5.6 Amp Draw On Condenser Fan - .6 Check Filter/Replace Clean Drain Test Blower Motor
Diane, R. Wheaton, IL
07-01-2021
Bryant 565BJ024-A
Heating Season - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Cooling Season: - Check Refrigeration Pressures - Test Safety Controls - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Clean Outdoor Condenser Coil - Clean Condensate Drains - Measure Temperature Difference - Test Cycle Unit - Change Filter ALL MEMBERS Receive: - Priority Service - 10% Member Discounts - Safer Homes - More Efficient Equipment - Great Value - Special Offers - Home Service Updates - Energy Savings- Investment Protection - Peace Of Mind Maintenance Agreement Add-on Thermostat Batteries Replace Batteries With Fresh New Batteries Maintenance Agreement Add-on Dryer Vent Cleaning Vaccum Out Dyer Vent Lint Maintenance Agreement Add-on Standard Water Heater Service Clean Sedemnt Out If Water Heater
Loretta, B. Wheaton, IL
06-23-2020
Carrier 38TZA036-3
Spring Preventive Maintenance Spring Start Up Clean Condenser Coils And Check For Damage Clean And Inspect Evaporator Coil Test And Check All Operational Pressures Monitor Refrigerant Pressure And Temperature Levels Test All Safety Controls Clean Drain Lines And Check For Blockage Calibrate Thermostat Inspect And Tighten All Electrical Connections Test Electrical Start And Run Capacitors Measure Starting In Running Amperage Lubricate Blower Bearings Monitor Fan Motor And Compressor Operating Temperatures
Peter, W. Wheaton, IL
06-16-2020
Carrier 399AAZ048080
AC Annual Maintenance 2020 Refrigeration - R22 HS LS Pressures Within Range Contactor - Marginal Capacitor - Good TD - 18 Degrees Clean Coils Of Cottonwood Seed And Dog Hair Unit Under Porch - Runs Inefficiently
Tracy, C. Wheaton, IL
06-12-2020
Annual Clean & Check Repair Added 1 LB Of 410A Refrigerant -$45 A LB Connected Pre-existing “C” Wire To 5 Year Old Nest ($20) Preventative Maintenance Program
Mike, K. Wheaton, IL
06-12-2020
Annual AC Clean & Check AC Tune Up
Andrew , G. Wheaton, IL
06-12-2020