Are you looking for gas furnace maintenance in West Chicago, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in West Chicago, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in West Chicago, IL

Get Your Quote Today

Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/ 0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Very Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Replaced Filter 10-25-22 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Steve , S. West Chicago , IL
10-29-2022
Furnace Report • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines, They Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Getting Rusty Inside But Working. • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues .
Tim , G. West Chicago , IL
10-15-2022
Furnace Report • Inducer Amps MNF/ - Test/0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/ Exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Very Clean Blue Flame No Cracks • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean/electronic • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Anke, K. West Chicago, IL
10-29-2022
Upon Arrival, Verified Sequence Of Operation Through Thermostat And Tested Mechanical Components Of Furnace And Everything Tested Between Manufacturing Specs. Inducer Motor Bearings Are Slightly Making Noise But Amping Between Range. Found Blower And Filter Extremely Dirty. Found Duct Work Very Dirty And Recommended Duct Cleaning And Then During Ac Cleaning We Do Blower Cleaning Then. Completed Humidifier Maintenance And Dryer Vent Cleaning During Visit.
Cathy, G. West Chicago, IL
04-10-2024
2nd-floor Furnace- Pre-clean-up Start-up Operations Are Good. The Interior Of The Furnace Has Rust, The Vent Motor Is Working A Bit On Amps, Blower Motor Amp Work Rate Is Good. Cleaned Up Motors Housing, The Interior Of The Furnace, Burner Assembly, Flame Sensor. Post-clean-up Start-up Operations Are Good. 1st-floor Furnace- Pre-clean-up Start-up Operations Are Good. Rusting Inside Furnace& Outside. Motors Are Working In A Good Operation Amp Range. Cleaned Up Motors Housing, The Interior Of The Furnace, Burner Assembly, Flame Sensor. Post-clean-up Start-up Operations Good. Both Furnaces Manufactured In July 2006, Current Filters Still Good, Recommend Change At The End Of The Month. I Checked The AC System @ Homeowner's Request, Having A Huge Amp Draw On The Condenser Closest To The Disconnect Wall. Amp Draw Is Way Too High For Operating Conditions. The Customer Would Like To Talk To Miguel About Replacement. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Kristin , W. West Chicago , IL
10-11-2021
Armstrong Furnace In Good Working Condition. Motors Work Well Under Their Amp Max Working Rate FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Dana , W. West Chicago , IL
09-21-2021
Upon Arrival. Furnace Operations Are Good. Amp Motors Are In Working Rate But Vent Motor A Bit High . Furnace Clean & Check FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Maria , D. West Chicago , IL
09-21-2021

Brian's Heatingstarstarstarstarstar4.6 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

49 Total Reviews /files//brians-logo.png630-333-3351$847 Weyrauch St. , West Chicago IL

©Red Barn Media Group 2025