Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Warrenville, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Warrenville, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Warrenville, IL

Get Your Quote Today

Upon Arrival, Verified Sequence Of Operations And Tested Mechanical Components Of Furnace. Everything Tested Between Manufacturer Specs. Cleared Clogged Humidifier Lines And Condensate Lines. Cleaned Air Purifier.
Kathy, L. Warrenville, IL
04-10-2024

Adam , C. Warrenville , IL
01-13-2023
Furnace Report: Furnace Report • Inducer Amps MNF/1.2 - Test/ • Clean Flame Sensor-yes • Blower Motor Capacitor MNF/ - Test/N/A • Inspect Wiring-yes • Inspect Burner-yes • Inspect Orifices For Blockage-yes • Carbon Monoxide Test-no • Inspect Chimney-yes • Inspect Pressure Switch Lines-yes • Test Sequence Of Operation-yes • Inspect Heat Exchanger-no • Check Ignitor-yes 50.0 • Check/replace The Filter-yes • Test Gas Shut Off-yes • Test Thermostat For Proper Operation-yes
Ron, P. Warrenville , IL
11-03-2022
Furnace Report • Inducer Amps MNF/.65 - Test/.54 • Clean Flame Sensor Clean Sensor Dirty • Blower Motor Capacitor MNF/ 15- Test/14.95 • Inspect Wiring No Issues • Inspect Burners No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor Spark Ignition Clean • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
David, C. Warrenville, IL
09-23-2022
Furnace Report: Furnace Report • Inducer Amps MNF/.56 - Test/.48 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/5 - Test/4.9 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Darlene, S. Warrenville, IL
02-25-2022
Furnace Report: Furnace Report • Inducer Amps MNF/.56 - Test/.48 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/5 - Test/4.9 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Darlene, S. Warrenville, IL
02-25-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Julianne , Y. Warrenville , IL
12-20-2021
Furnace Report: Furnace Report 1st Floor • Inducer .65 @.45 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Chris , S. warrenville, IL
12-20-2021
Furnace Report • Inducer Amps MNF/1.45 - Test/1.45 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Carol , R. Warrenville , IL
11-22-2021
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Robert , T. Warrenville , IL
11-05-2021
Upon Arrival Pre-clean Start-up Operations Are Good. Motors Are Working Within The Operating Amp Rate. Interior Kept Well Maintained. Cleaned Up The Interior Of The Furnace, Flame Sensor, Motor Housings, Burner Assembly. Post-clean-up Start-up Operations Good. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Kathryn , D. Warrenville, IL
10-29-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Flame Sensor Was Really Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly. The Current Filter Looks Fairly New .post Clean-up Start-up Operations Are Good. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Ron , G. Warrenville , IL
10-21-2021
Upon Arrival Pre Clean Up, Furnace Start-up Operations Are Good. Motors Amps Within Operation Rate. The Furnace Air Filter Really Dirty, The Flame Sensor Was A Bit Dirty. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor & Burner’s Assembly & Put In A New Furnace Air Filter (homeowner Provided). Post Clean Start-up Operations Good. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Maureen, G. Warrenville, IL
10-21-2021
Upon Arrival, Outdoor Ac Fan Motor Was Running A Bit High Possibly Due To Dirty Condenser, After Clean Up Amps Went Down. Furnace Motors Are All In Good Working Rate & Cleaned Up Flame Sensor & Furnace Interior FPM Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter ACPM Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure -273/9 Low Pressure - 129/17 Ambient Temp - 70 Delta T Reading -19 Contactor Resistance Reading -19.5 Low Voltage Wiring Check Capacitor Reading 40/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor -6 Amps Amp Draw On Condenser Fan -.7 Check Filter/Replace Clean Drain Test Blower Motor