Are you looking for Air Conditioning maintenance in Warrenville, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Warrenville, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.

We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.

We provide Air Conditioning Maintenance in Warrenville, IL

We provide Air Conditioning Maintenance Agreements in Warrenville, IL

Get Your Quote Today

Completed Two Ac Clean And Checks. First Floor: Inspected Blower Department And Found Capacitor Out Of Specifications. Recommended Replacement And Homeowner Agreed Continued Replace. Continued Inspection To Outdoor Unit And Tested Mechanical And Refrigerant Levels And Everything Was Up To Manufacturing Specifications. Please Reference Tune Up Form For Specifications. Second Floor: Inspected Blower Department. Continued Inspection To Outdoor Unit And Tested Mechanical And Refrigerant Levels And Everything Was Up To Manufacturing Specifications. Please Reference Tune Up Form For Specifications. Recommended Replacing Thermostats As They Jump Temp, Button Sticks And Is Out Of Date Also. This Was A Issue Last Visit. Homeowner Declined Replacement But I Did Leave Estimate In Case He Does Want To Replace In The Future.
Dan, R. warrenville, IL
04-02-2024
Completed Two Ac Clean And Checks. First Floor: Inspected Blower Department And Found Capacitor Out Of Specifications. Recommended Replacement And Homeowner Agreed Continued Replace. Continued Inspection To Outdoor Unit And Tested Mechanical And Refrigerant Levels And Everything Was Up To Manufacturing Specifications. Please Reference Tune Up Form For Specifications. Second Floor: Inspected Blower Department. Continued Inspection To Outdoor Unit And Tested Mechanical And Refrigerant Levels And Everything Was Up To Manufacturing Specifications. Please Reference Tune Up Form For Specifications. Recommended Replacing Thermostats As They Jump Temp, Button Sticks And Is Out Of Date Also. This Was A Issue Last Visit. Homeowner Declined Replacement But I Did Leave Estimate In Case He Does Want To Replace In The Future.
Dan, R. Warrenville, IL
04-01-2024
A/C Report: A/C Report 2nd Floor Clean And Check Outdoor Condenser High Pressure - 220 Low Pressure - 63 Ambient Temp - 80 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading - 35/5 @ 35.5/5.2 Clean Out Electrical Compartment Cleaned Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit Check Filter/Replace Air Filter Needs To Be Replaced Clean Drain No Issues Test Blower Motor No Issues A/C Report: A/C Report 1st Floor Unit Clean And Check Outdoor Condenser High Pressure - 285 Low Pressure - 125 Ambient Temp - 80 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check - No Issues Capacitor Reading - 40/5 @ 39.32/5.14 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation - Well Insulated Service Valve Cap - No Issues Amp Draw On Compressor - 12.8 @6.05 Amp Draw On Condenser Fan - 1.0 @.60 Lock Rotor Amps - 67.8 @ 72.2 Check Filter/Replace Air Filter Needs To Be Replaced Clean Drain No Issues Test Blower Motor No Issues
Chris , S. warrenville, IL
06-03-2022
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 116 Low Pressure - 250 Ambient Temp - 67 Delta T Reading -19 Contactor Resistance Reading - Low Voltage Wiring Check No Issues Capacitor Reading 40/[email protected]/4.4 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan - [email protected] Lock Rotor Amps - 64@ 68.8 Recommended Hard Start Kit 55.6 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Maureen, G. Warrenville, IL
05-19-2022
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 220 Low Pressure - 118 Ambient Temp - 65 Delta T Reading -17 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/[email protected]/5.01 Replaced Cap Clean Out Electrical Compartment Cleaned Spider Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -6.8@ 3.53 Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - 38.6@ 27.2 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Ashley & James, G. Warrenville, IL
05-19-2022
Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure/Subcooling - 152/13 Low Pressure/Hyper Heat - 60/25 Ambient Temp - 60 Delta T Reading -10 Amp Draw On Compressor -17 Amp Draw On Condenser Fan -.7 Contactor Resistance Reading -18 Low Voltage Wiring Check Capacitor Reading 30/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Check Filter/Replace Clean Drain Test Blower Motor
Robert , T. Warrenville , IL
09-09-2021
Trane 4TTB3036E1000AA
Make: TRANE - 2013 MN: 4TTB6024A1000A SN:13313L2D5F Clean And Check Outdoor Condenser High Pressure - Refrigerant Check - 279 Psig Low Pressure - Refrigerant Check - 137 Psig 86 Degree Ambient Delta T Reading Contractor Resistance Reading -0 Resistance Low Voltage Wiring Check - 24 Capacitor Reading - 35/5 MFD - Marginal Pre-Existing - Hard Start With Relay #147P03 Clean Out Electrical Compartment - Good Refrigeration Line Check - Low Side Insulation -good Service Valve Cap -yes Amp Draw On Compressor - 3.46 Amp Draw On Condenser Fan - .74 Heating Season - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Cooling Season: - Check Refrigeration Pressures - Test Safety Controls - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Clean Outdoor Condenser Coil - Clean Condensate Drains - Measure Temperature Difference - Test Cycle Unit - Change Filter ALL MEMBERS Receive: - Priority Service - 10% Member Discounts - Safer Homes - More Efficient Equipment - Great Value - Special Offers - Home Service Updates - Energy Savings- Investment Protection - Peace Of Mind Optional Add-ons: Humidifier Pad - $35 Media Filter - $25/50 Dryer Vent Cleaning - Starting At $50 Standard Tank Water Heater Service - $50 Tankless H.E Water Heater Service- $110 Thermostat Batteries - $10 Standard Box Of Filters - $30 Additional A/C Unit - $110 Additional Furnace - $110 Terms: By Signing This Agreement, You Understand And Agree That This Agreement Shall Last For Exactly 1 Year From Time Of Purchase And That After Expiring, Brian's Heating And Air Conditioning May Renew Your Membership With Verbal Approval (either Over The Phone Or In Person) Without The Need For A New Signature. Brian's Heating And Air Conditioning Has Final Authority To Modify Any Pricing Of
Ashley & James, G. Warrenville, IL
06-19-2020
Carrier CA13NA048
Preventative Maintenance Program Your Customized Service Plan Includes: Heating Season - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Cooling Season: - Check Refrigeration Pressures - Test Safety Controls - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Clean Outdoor Condenser Coil - Clean Condensate Drains - Measure Temperature Difference - Test Cycle Unit - Change Filter ALL MEMBERS Receive: - Priority Service - 10% Member Discounts - Safer Homes - More Efficient Equipment - Great Value - Special Offers - Home Service Updates - Energy Savings- Investment Protection - Peace Of Mind AC Report Clean And Check Outdoor Condenser High Pressure - 325 Low Pressure - 120 Delta T Reading 20 Contractor Resistance Reading 0 Low Voltage Wiring Check Capacitor Reading - 40/4.69 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 6.15 Amp Draw On Condenser Fan - .64 Check Filter/Replace Clean Drain Test Blower Motor