Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in St. Charles, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in St. Charles, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in St. Charles, IL

Get Your Quote Today

Furnace Report • Inducer Amps MNF/ - Test/2.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Clear Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report Furnace 2nd Floor • Inducer Amps MNF/ - Test/0.3A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Replaced Filter 10-20-22 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Joe , D. St. Charles , IL
10-22-2022
Furnace Report: Furnace Report • Inducer .46 @ .39 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Kyle, D. St. Charles , IL
01-11-2022
Upon Arrival Pre Clean Up Start Up Operations Are Good. Interior Of Furnace Was A Bit Dirty. Cleaned Up Interior Of Furnace, Flame Sensor, Burner Assembly & Motors Housing . Changed CFM On Blower Per Customer Request . Post Clean Up Start Up Operations Are Good . Motors Are Working Well Within Amp Rate . Current Filter Is Pretty Clean. Did A Walkthrough On His AC Leak Dye Purchase. Did Not Find Leak Or Any Dye. We Will Do Another Check When Doing His AC Maintenance .
Micheal, W. St. Charles, IL
10-29-2021
Upstairs Furnace- Pre Clean Up Star Up Operations Good. Cleaned Up Flame Sensor, Burner Assembly, The Interior Of The Furnace, Motor Housing. Operation Amps On The Motor Are Within Amp Rate, The Current Filter Still Good. A Humidifier In Good Working Order Changed Out The Water Panel. Downstairs Furnace- Pre Clean Up Star Up Operations Good. Cleaned Up Flame Sensor, Burner Assembly, The Interior Of The Furnace, Motor Housing. Operation Amps On The Motor Are Within Amp Rate, The Current Filter Still Good. The Humidifier In Good Working Order Changed Out Water Panel & Replace Drain Hose. Water Heater Service- Replace Temp Relief Valve With New One, After Install Tested And Made Sure Pilot Was Back On. Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Joe , D. St. Charles , IL
10-21-2021
Upon Arrival, Pre-cleanup Start-up Operations Are Good In The Furnace. Interior In Good Condition. Cleaned Motor Housing, The Interior Of The Furnace, Burner Assembly, Flame Sensor. Motors Working Within Amp Operation Rate. Current Filter Still Good. Post-clean-up Start-up Operations Are Good. Helped Customer With Questions Of Operating The A3 Thermostat Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Sandy , C. St. Charles , IL
10-13-2021

Brian's Heatingstarstarstarstarstar4.6 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

49 Total Reviews /files//brians-logo.png630-509-8310$847 Weyrauch St. , West Chicago IL

©Red Barn Media Group 2024