Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Oak Brook, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Oak Brook, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Oak Brook, IL

Get Your Quote Today

Furnace Report: Furnace Report Twinned Furnace #1 • Inducer Amps MNF/ - Test/ 2.2A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good. Clean Blue Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Recommend Replacing Filters • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report • Inducer Amps MNF/ - Test/2.0A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues Clean Blue Flame • Check Ignitor • Check/replace The Filter Replaced Filter 10-31-2022 • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Anne , H. Oak Brook, IL
11-03-2022
Furnace Report: Furnace Report Twin 1 • Inducer 2.8 @ 2.4 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Furnace Report: Furnace Report Twin 2 • Inducer. 2.8 @. 2.5 • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney NA • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Anne , H. Oak Brook, IL
12-20-2021
Furnace Report 1st Floor • Inducer Amps MNF/2.8 - Test/.38 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger (Heavy Rust) • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation Furnace Report 2nd Floor • Inducer Amps MNF/2.8 - Test/2.28 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger (light Rust) • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Matt , K. Oak Brook, IL
12-01-2021
2 Furnaces* Upon Arrival, Pre-clean-up Start-up Operations Are Good. Motors In Both Furnaces Work Well Within The Operation Amp Rate. Switches Are Good, Flame Sensor Dirty & Burner Assembly Dirty In Both Furnaces. Cleaned Up Motor Housing, Flame Sensor, Burner Assembly & Interior Of The Furnace. Furnaces Manufactured In 9/2005. Humidifier Maintenance Offered & Homeowner Accepted. Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Melissa , B. Oak Brook , IL
10-20-2021

Brian's Heatingstarstarstarstarstar4.6 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

49 Total Reviews /files//brians-logo.png630-509-8310$847 Weyrauch St. , West Chicago IL