Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Lombard, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Lombard, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Lombard, IL

Get Your Quote Today

Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Stephanie , J. Lombard , IL
01-14-2022
Vent Motor Is Running At 2.5 Amps. Rated For 1.6 Amps . Blower Motor Is In Good Amp Range. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Mohammed, A. Lombard, IL
09-28-2021
Furnace Report: Furnace Report • Inducer [email protected] • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Issues Dusty • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter No Issues • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Michael , C. Lombard , IL
01-14-2022
Furnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor Dirty • Inspect Blower Motor Adjusted Blower Speed To -12% • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Terry , M. Lombard , IL
01-20-2022
Furnace Report • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Cleared • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Has No Cracks,, Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean Was Just Replaced • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Kris , B. Lombard, IL
09-29-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ .5- Test/.35 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/35 - Test/35.4 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - Low Pressure - Ambient Temp - Delta T Reading - Contactor Resistance Reading - Low Voltage Wiring Check Capacitor Reading Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - Amp Draw On Condenser Fan - Check Filter/Replace Clean Drain Test Blower Motor
Raymond , F. Lombard , IL
03-21-2022