Air Conditioning Maintenance
Are you looking for Air Conditioning maintenance in Lombard, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Lombard, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.
We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.
We provide Air Conditioning Maintenance in Lombard, IL
We provide Air Conditioning Maintenance Agreements in Lombard, IL
Furnace Report
• Inducer Amps MNF/1.5 - Test/1.2
• Clean Flame Sensor Cleaned Sensor Dirty
• Blower Motor Capacitor MNF/5 - Test/4.9
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orifices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter Air Filter Looks Good
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
A/C Report:
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 198
Low Pressure - 68
Ambient Temp - 75
Delta T Reading -20
Contactor Resistance Reading -no Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 35/5@ 34.2/3.4
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -14.1
Amp Draw On Condenser Fan -1.1
Lock Rotor Amps - 67
Check Filter/Replace Filter Look Good
Clean Drain No Issues
Test Blower Motor No Issues
sarah , E. Lombard , IL
06-11-2022
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 180
Low Pressure - 110
Ambient Temp - 55
Delta T Reading -18
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 45/10@45.35/9.73
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -17.9@6.89
Amp Draw On Condenser Fan -1.7@1.10
Lock Rotor Amps - 113@119.2 Recommended Hard Start Kit
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
Paul, G. Lombard, IL
05-27-2022
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 259
Low Pressure - 120
Ambient Temp - 80
Delta T Reading -19
Contactor Resistance Reading - 4.1
Low Voltage Wiring Check No Issues
Capacitor Reading 40/5@38.90/4.9
Clean Out Electrical Compartment No Issues
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -15.3@6.27
Amp Draw On Condenser Fan -1.1@.68
Lock Rotor Amps - 83@78.4
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
Richard , G. Lombard , IL
05-27-2022
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 190
Low Pressure - 120
Ambient Temp - 50
Delta T Reading -18
Contactor Resistance Reading -4.0
Low Voltage Wiring Check No Issues
Capacitor Reading 35/5@35.01/5.07
Clean Out Electrical Compartment Cleaned Webs
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -12.1@3.69
Amp Draw On Condenser Fan -1.0@.68
Lock Rotor Amps - 59.3@65.9
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
Furnace Report
• Inducer Amps MNF/ .65- Test/.53
• Clean Flame Sensor Cleaned Sensor
• Blower Motor Capacitor MNF/ - Test/ NA
• Inspect Wiring No Issues
• Inspect Burner No Issues
• Inspect Orifices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace The Filter Air Filter Looks Good
• Test Gas Shut Off No Issues Replaced Gas Stop On Water Heater
• Test Thermostat For Proper Operation No Issues
Aaron , F. Lombard , IL
05-05-2022
Upon Arrival. Outdoor AC Unit Fan Motor Working A Bit High . After Clean Up , Amps Went Down.
ACPM Annual A/C Preventative Maintenance:
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure - 285/4
Low Pressure - 115/3
Ambient Temp - 80
Delta T Reading -50
Contactor Resistance Reading -18
Low Voltage Wiring Check
Capacitor Reading 45/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor -10
Amp Draw On Condenser Fan -1
Check Filter/Replace
Clean Drain
Test Blower Motor
Jeff , G. Lombard, IL
09-21-2021
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
ACPM Annual A/C Preventative Maintenance:
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure - 303/5
Low Pressure - 132/17
Ambient Temp - 75
Delta T Reading -26
Contactor Resistance Reading -19
Low Voltage Wiring Check
Capacitor Reading 35/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor -5.7
Amp Draw On Condenser Fan -.5
Check Filter/Replace
Clean Drain
Test Blower Motor
Jane Rosita , A. Lombard , IL
09-20-2021
ACPM Annual A/C Preventative Maintenance:
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure - 303/5
Low Pressure - 132/17
Ambient Temp - 75
Delta T Reading -26
Contactor Resistance Reading -19
Low Voltage Wiring Check
Capacitor Reading 35/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor -5.7
Amp Draw On Condenser Fan -.5
Check Filter/Replace
Clean Drain
Test Blower Motor
Jane, A. Lombard, IL
09-13-2021