Air Conditioning Maintenance

Air Conditioning Maintenance

Are you looking for Air Conditioning maintenance in Lombard, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Lombard, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.

We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.

We provide Air Conditioning Maintenance in Lombard, IL

We provide Air Conditioning Maintenance Agreements in Lombard, IL

Get Your Quote Today

A/C Report Clean And Check Outdoor Condenser High Pressure - 259 Low Pressure - 120 Ambient Temp - 80 Delta T Reading -19 Contactor Resistance Reading - 4.1 Low Voltage Wiring Check No Issues Capacitor Reading 40/[email protected]/4.9 Clean Out Electrical Compartment No Issues Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Richard , G. Lombard , IL
05-27-2022
ACPM Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 303/5 Low Pressure - 132/17 Ambient Temp - 75 Delta T Reading -26 Contactor Resistance Reading -19 Low Voltage Wiring Check Capacitor Reading 35/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor -5.7 Amp Draw On Condenser Fan -.5 Check Filter/Replace Clean Drain Test Blower Motor
Jane, A. Lombard, IL
09-13-2021
Furnace Report • Inducer Amps MNF/1.5 - Test/1.2 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/5 - Test/4.9 • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 198 Low Pressure - 68 Ambient Temp - 75 Delta T Reading -20 Contactor Resistance Reading -no Issues Low Voltage Wiring Check No Issues Capacitor Reading 35/5@ 34.2/3.4 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor -14.1 Amp Draw On Condenser Fan -1.1 Lock Rotor Amps - 67 Check Filter/Replace Filter Look Good Clean Drain No Issues Test Blower Motor No Issues
sarah , E. Lombard , IL
06-11-2022
A/C Report Clean And Check Outdoor Condenser High Pressure - 190 Low Pressure - 120 Ambient Temp - 50 Delta T Reading -18 Contactor Resistance Reading -4.0 Low Voltage Wiring Check No Issues Capacitor Reading 35/[email protected]/5.07 Clean Out Electrical Compartment Cleaned Webs Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues Furnace Report • Inducer Amps MNF/ .65- Test/.53 • Clean Flame Sensor Cleaned Sensor • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues Replaced Gas Stop On Water Heater • Test Thermostat For Proper Operation No Issues
Aaron , F. Lombard , IL
05-05-2022
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter ACPM Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 303/5 Low Pressure - 132/17 Ambient Temp - 75 Delta T Reading -26 Contactor Resistance Reading -19 Low Voltage Wiring Check Capacitor Reading 35/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor -5.7 Amp Draw On Condenser Fan -.5 Check Filter/Replace Clean Drain Test Blower Motor
Jane Rosita , A. Lombard , IL
09-20-2021
A/C Report Clean And Check Outdoor Condenser High Pressure - 180 Low Pressure - 110 Ambient Temp - 55 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 45/[email protected]/9.73 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Paul, G. Lombard, IL
05-27-2022

Brian's Heatingstarstarstarstarstar4.6 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

49 Total Reviews /files//brians-logo.png630-509-8310$847 Weyrauch St. , West Chicago IL