Are you looking for gas furnace maintenance in Hinsdale, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Hinsdale, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Hinsdale, IL
A/C Report:
A/C Report Upstairs
Clean And Check Outdoor Condenser
High Pressure - 205
Low Pressure - 108
Ambient Temp - 45
Delta T Reading - 18
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 45/5@ 44.56/5.06
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor - 15.3 @ 5.98
Amp Draw On Condenser Fan - 1.1 @ .61
Lock Rotor Amps - 83 @ 63.1
Check Filter/Replace Replaced AA210
Clean Drain No Issues
Test Blower Motor No Issues
A/C Report:
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 206
Low Pressure - 110
Ambient Temp - 45
Delta T Reading - 18
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 45/5 @ 44.78/5.02
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -15.3 @6.08
Amp Draw On Condenser Fan -1.1 @ .71
Lock Rotor Amps - 83 @67.3
Check Filter/Replace Air Filter Needs To Be Replaced
Clean Drain No Issues
Test Blower Motor No Issues
Cristian , H. Hinsdale , IL
04-29-2022
Furnace Report:
Furnace Report Front
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor Dirty
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Air Filter Needs To Be Replaced
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Furnace Report:
Furnace Report Back Of House
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Air Filter Needs To Be Replaced
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Diana , W. Hinsdale, IL
01-25-2022
Furnace Report:
Furnace Report
• Inducer .30@.25
• Clean Flame Sensor Cleaned Sensor
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Issues
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Told Customer Should Replace Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Timothy, A. Hinsdale, IL
01-14-2022
Furnace Report:
Furnace Report
• Inducer. I Issues
• Clean Flame Sensor Cleaned Sensor
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner Some Rust No Issues
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Air Filter Looks Clean
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
John , T. Hinsdale , IL
12-27-2021
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Mitsubishi Tune Up
Remove Filters And Clean
Check Drains For Blockage
Clean Coils
Clean Outdoor Coils
Christian , n. Hinsdale , IL
12-01-2021
Upstairs Furnace - Pre Clean Up Start-up Operations Good, Vent Motor Working A Bit High Based On Operations Amp Rate, Amp Rate Is .75 & It's Running At 1.5, Blower Motor In Good Operation Amps. Interior Of Furnace Mild Rust Built Up. Cleaned Up The Interior Of The Furnace, Motor Housing, FlAme Sensor, Burner Assembly, Post Clean Up Start-up Operations Good. Manufactured In September 2002
Basement Furnace-pre Cleanup Start-up Operations Good, A Lot Of Interior Rust, Motors In This Furnace Are Within Proper Amp Rate But Definitely Has A Lot More Interior Rust Than The Furnace Upstairs. Cleaned Up The Interior Of The Furnace, Motor Housings, Flame Sensor, Burner Assembly & Also Manufactured In September 2002.
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Markus, H. Hinsdale, IL
10-22-2021