Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Elmhurst, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Elmhurst, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Elmhurst, IL

Get Your Quote Today

Furnace Report: Furnace Report Furnace 1st Floor Front Of The House • Inducer Amps MNF/ - Test/2.2A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call, No Issues Furnace Report: Furnace Report Furnace 1st Floor Back Of The House • Inducer Amps MNF/ - Test/2.7A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleaned And Cleared • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues Clean Flame No Cracks • Check Ignitor Ignitor Is Good • Check/replace The Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Trever , W. Elmhurst , IL
10-22-2022
Urnace Report: Furnace Report Furnace 1st Floor • Inducer Amps MNF/ - Test/2.7A • Clean Flame Sensor No Flame Sensor/ Pilot • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Burners Are Very Rusty. Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines, No Obstructions • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is 18 Years Old, Could Begin To Crack • Check Ignitor No Issues • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report: Furnace Report Furnace 2nd Floor • Inducer Amps MNF/ - Test/1.3A • Clean Flame Sensor N/A Pilot • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Burners Are A Little Rusty, Still Cleaned Them And They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines No Obstructions • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Due To Age Could Possible Begin To Be Damaged/crack • Check Ignitor PILOT • Check/replace The Filter REPLACED FILTER • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Danish , Y. Elmhurst , IL
10-15-2022
Furnace Report Furnace 1st Floor • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Free Of Obstruction • Test Sequence Of Operation Sequence Of Operations S Good And In Order • Inspect Heat Exchanger Heat Exchanger Gas No Cracks, Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues T Furnace Report: Furnace Report Furnace 2nd Floor • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned Burners, They Are Free Of Obstruction • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Pressure Switch Lines Are Cleared • Test Sequence Of Operation Sequence Of Operations Are Good And In Order • Inspect Heat Exchanger No Cracks, Clean Flame • Check Ignitor Ignitor Has Good Continuity • Check/replace The Filter Filter Is Clean • Test Gas Shut Off Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Patrick , H. Elmhurst , IL
09-29-2022
Furnace Report: Furnace Report • Inducer Mmf 2.4 @2.1 • Clean Flame Sensor Cleaned • Inspect Blower Motor Dusty But Cleaned • Inspect Wiring No Issues • Inspect Burner No Issues • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney Na • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Changed Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Anthony , W. Elmhurst, IL
12-14-2021
Furnace Report • Inducer Amps MNF/1.0 - Test/.75 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation
Don & Joan, H. Elmhurst, IL
11-24-2021