Are you looking for Air Conditioning maintenance in Downers Grove, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Downers Grove, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.

We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.

We provide Air Conditioning Maintenance in Downers Grove, IL

We provide Air Conditioning Maintenance Agreements in Downers Grove, IL

Get Your Quote Today

Completed Ac Clean And Check. Found Air Filter To Be Extremely Dirty And Took Out For Testing Purposes And Let Homeowner Know To Replace It Soon. Tested Blower Department And Tested Ac Unit Mechanical Components And Refrigerant Levels To Be Good. Recommended Hard Start Kit
Barbra, W. Downers Grove, IL
04-08-2024
Upon Arrival, Verified Sequence Of Operation Through Thermostat And Tested Blower Department And Changed Filter And Humidifier Pad Provided By Homeowner. Tested Mechanical And Refrigerant Levels And Everything Was Up To Manufacturing Specifications. Cleaned Condenser Coil.
Arielle , B. Downers Grove , IL
04-08-2024
Completed Ac Clean And Check. Found Air Filter To Be Extremely Dirty And Took Out For Testing Purposes And Let Homeowner Know To Replace It Soon. Tested Blower Department And Tested Ac Unit Mechanical Components And Refrigerant Levels To Be Good. Recommended Hard Start Kit But Homeowner Declined At This Time. Left Estimate. Renewed Membership Agreement During Visit.
Barbara, W. Downers Grove, IL
04-05-2024
Upon Arrival, Verified Sequence Of Operation Through Thermostat And Tested Blower Department And Changed Filter And Humidifier Pad Provided By Homeowner. Tested Mechanical And Refrigerant Levels And Everything Was Up To Manufacturing Specifications. Cleaned Condenser Coil.
Arielle , B. Downers Grove , IL
04-05-2024
Upon Arrival, Verified Sequence Of Operation Through Thermostat And Inspected Blower Department. Continued Inspection Of Unit Outside And Tested Refrigerant Levels And Cleaned Condenser Coil. Please Reference Tune Up Form For Details.
Lisa, S. Downers grove, IL
04-01-2024
A/C Report Clean And Check Outdoor Condenser High Pressure - 245 Low Pressure - 126 Ambient Temp - 75 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 40/5@ Clean Out Electrical Compartment No Issues Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Olena , S. Downers Grove , IL
06-11-2022
A/C Report: A/C Report 2nd Floor Clean And Check Outdoor Condenser High Pressure - Low Pressure - Ambient Temp - Delta T Reading - Contactor Resistance Reading - Low Voltage Wiring Check Wires All Chewed Up Capacitor Reading 35/5 @ 31.4/4.06 Clean Out Electrical Compartment Mice Nest Found Wires Chewed Up Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor - Amp Draw On Condenser Fan - Lock Rotor Amps - Check Filter/Replace Clean Drain Test Blower Motor A/C Report: A/C Report 1st Floor Clean And Check Outdoor Condenser High Pressure - 108 Low Pressure - 214 Ambient Temp - 60 Delta T Reading - 18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 45/5 @ 44.67/4.89 Clean Out Electrical Compartment Clean Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor - 16.7 @ 7.26 Amp Draw On Condenser Fan -1.1 @ .54 Lock Rotor Amps - 70 @77.8 Recommended Hard Start Kit Check Filter/Replace Air Filter Needs To Be Replaced Clean Drain No Issues Test Blower Motor No Issues
Reid, H. Downers Grove, IL
04-29-2022
Annual A/C Preventative Maintenance: Upstairs Unit Clean And Check Outdoor Condenser High Pressure - 275 Low Pressure - 100 Ambient Temp - 75 Delta T Reading - Contactor Resistance Reading - Low Voltage Wiring Check Capacitor Reading - 45/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 6.0 Amp Draw On Condenser Fan - .7 Check Filter/Replace Clean Drain Test Blower Motor ACPM Annual A/C Preventative Maintenance: Annual A/C Preventative Maintenance: Downstairs Unit Clean And Check Outdoor Condenser High Pressure - 260 Low Pressure - 105 Ambient Temp - 75 Delta T Reading - Contactor Resistance Reading - Low Voltage Wiring Check Capacitor Reading 45 / 4.5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 9.8 Amp Draw On Condenser Fan - 1.3 ( Running High ) Check Filter/Replace Clean Drain Test Blower Motor
Jim, J. Downers Grove, IL