Gas Furnace Maintenance
Are you looking for gas furnace maintenance in Carol Stream, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Carol Stream, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace Maintenance Agreements in Carol Stream, IL
Upon Arrival, Furnace Operations Are Good. Motors Working Within Operating Amp Rate. Cleaned Up Motor Housing, Burner Assembly, Flame Sensor & Interior Of The Furnace. Also Offered Humidifier Maintenance & Homeowner Accepted. The Humidifier In Good Operations
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Airflow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Set Manual Controls @ 35% For Winter Opperaion.
Verify Automatic Control Set In WiFi Stat
Scott, P. Carol Stream, IL
10-08-2021
Furnace Report:
Furnace Report
• Inducer No Issues
• Clean Flame Sensor Cleaned Sensor Dirty
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Replaced Air Filter
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
Jim& Joy, D. Carol Stream, IL
01-27-2022
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Inducer Amp Draw - 1.4
- Change Filter
Paulette , N. Carol Stream , IL
09-15-2021
Furnace Report
• Inducer Amps MNF/1.1 - Test/.30 (Bearings Failing)
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Carbon Monoxide Test
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger (Rust In Drain)
• Check Ignitor
• Check/replace Filter
• Test Gas Shut Off
• Test Thermostat For Proper Operation
Ed, W. Carol Stream, IL
11-22-2021
Upon Arrival, Verified Sequence Of Operation And Tested Mechanical Components Of Furnace And Found Everything To Be Between Manufacturing Specs. Homeowner Mentioned How She Didn’t Remember How To Work Dampers Explained How To Use Dampers.
Jenna , S. Carol Stream , IL
04-10-2024
Furnace Report
• Inducer Amps MNF/1.3 - Test/1.17
• Clean Flame Sensor
• Inspect Blower Motor
• Inspect Wiring
• Inspect Burner
• Inspect Orfices For Blockage
• Inspect Chimney
• Inspect Pressure Switch Lines
• Test Sequence Of Operation
• Inspect Heat Exchanger
• Check Ignitor
• Test Gas Shut Off
• Test Thermostat For Prope
Cody , A. Carol Stream , IL
11-22-2021
Furnace Report:
Furnace Report
• Inducer Motor Has A Chatter When It Starts Up
• Clean Flame Sensor Cleaned Sensor Dirty
• Inspect Blower Motor No Issues
• Inspect Wiring No Issues
• Inspect Burner No Rust
• Inspect Orfices For Blockage Cleared All Ports
• Carbon Monoxide Test 0ppm Found
• Inspect Chimney No Issues
• Inspect Pressure Switch Lines No Issues
• Test Sequence Of Operation No Issues
• Inspect Heat Exchanger No Issues
• Check Ignitor No Issues
• Check/replace Filter Needs To Be Replaced
• Test Gas Shut Off No Issues
• Test Thermostat For Proper Operation No Issues
John , H. Carol Stream , IL
01-27-2022