Furnace Service and Repair

Furnace Service and Repair

If your gas furnace in Carol Stream, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Carol Stream, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Carol Stream, IL

We provide gas furnace repair in Carol Stream, IL

Get Your Quote Today

Upon Arrival Furnace Operations Were Good But The Flame Sensor Was Not Catching Proper Flame Detection & It Was Really Dirty. Also, The Burners Were Not Properly Aligned Causing The Flame Rollout Switch To Open. After Furnace Maintenance, Clean Up & Re-adjusting Position Of Flame Sensor & Burners .furnace Operations Are Good, Flame Sensor Is Getting Proper Micro Amps Based On Manufacturing. Cleaned Up Motor Housing, The Interior Of The Furnace, Flame Sensor, Burner Assembly. Post-clean-up Start-up Operations Good. Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Edelina , B. Carol Stream , IL
10-29-2021
"No Heat" On Arrival. Was Not Getting Ignition. Replaced Circuit Board And Igniter.
Cary, D. Carol Stream, IL
04-24-2019
Urnace Report: Furnace Report • Inducer No Issues • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor Found Cap Rated @[email protected] • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage No Issues • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Bill , S. Carol Stream, IL
01-06-2022
Furnace Report: Furnace Report • Inducer Amps MNF/ 1.05- Test/.95 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Michael , P. Carol Stream , IL
03-25-2022