Are you looking for Air Conditioning maintenance in Carol Stream, IL ? Our AC and Air Conditioning service technicians have years of experience working on Central AC Systems like yours in Carol Stream, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your Cooling System back up and operating.

We offer Central Air Conditioner maintenance and maintenance agreements to keep your AC system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency Air Conditioner today.

We provide Air Conditioning Maintenance in Carol Stream, IL

We provide Air Conditioning Maintenance Agreements in Carol Stream, IL

Get Your Quote Today

Armstrong HVAC 4SCU16LE148P-4
A/C Report Preventative Maintenance Program
Bill, S. Carol Stream, IL
06-12-2020
A/C Report: A/C Report Clean And Check Outdoor Condenser High Pressure - 260 Low Pressure - 121 Ambient Temp - 74 Delta T Reading -19 Contactor Resistance Reading - No Issues Low Voltage Wiring Check Capacitor Reading 45/[email protected]/4.8 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap In Place Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Recommended Hard Start Kit 61.4 Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Jim, D. Carol Stream, IL
09-23-2022
Completed Ac Tune Up. Inspected Blower Department And TD Of 19 And Continued Inspection Outdoor Unit Mechanical Components And Ac Refrigerant Levels Are All To Specifications. Cleaned Condenser Coil. Please Reference Tune Up Form For Details. Renewed Agreement During Visit.
Nick, S. Carol Stream, IL
04-09-2024
American Standard HVAC 4TTB3030*
Clean And Check Outdoor Condenser High Pressure - 295 Low Pressure - 100 Delta T Reading 20 Contractor Resistance Reading 0 Low Voltage Wiring Check Capacitor Reading - 49.5/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 7.6 Amp Draw On Condenser Fan .67 Check Filter/Replace Clean Drain Test Blower Motor Capacitor Marginal System Low On Refrigerant 410A Refrigerant Weigh In Refrigerant Charge System To Proper Operating Pressures 125/300 Ps Preventative Maintenance Program Clean And Check Outdoor Condenser High Pressure - Refrigerant Check Low Pressure - Refrigerant Check Delta T Reading Contractor Resistance Reading Low Voltage Wiring Check Capacitor Reading Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor Amp Draw On Condenser Fan
Jim , V. Carol Stream, IL
06-30-2020
Upon Arrival, Homeowner Mentioned How Upstairs Gets Warm And Explained That Eco Bee Have A Fan Circulation Option Or Her Current Thermostat Can Have Fan On All The Time But Cause Her Motor To Run More. This Will Help With Bring The Upstairs Temp Down. Continued Inspection To Indoor Unit And Found Filter Dirty And Took Out Of System And Recommended Replacing Filter Asap. Blower Wheel Is Dirty And Recommended Blower Cleaning But Homeowner Declined At This Time. Continued Inspection Outdoor And Everything Tested Between Manufacturing Specifications. Please Reference Tune Up Form. End Of Visit We Spoke About UV Light And It’s Benefits As She Suffers From Allergies And This Can Help Keep Air Clean Inside The House. Especially After They Clean Their Ducts. She Requested To Leave Estimate For All This. Which Is Attached. This Visit Was Part Of Membership Agreement.
Jason, A. Carol Stream, IL
04-12-2024
Upon Arrival, I Met Paulette, Who Kindly Showed Me The Thermostat, Furnace, And Condenser. I Inspected The Blower And Filter, And Replaced The Filter Provided By The Client. I Then Located The Condenser Outside And Completed The AC Maintenance According To The Checklist. During The Inspection, I Found That The Dual Capacitor Reading Was Low. Given That The Unit Is Three Years Old, The Part Is Covered Under Warranty, Though Labor Is Not Included. I Replaced The Dual Capacitor Under Warranty. The Unit Is Now Functioning Properly.
Paulette , N. Carol Stream , IL
06-12-2024
A/C Report Clean And Check Outdoor Condenser High Pressure - 205 Low Pressure - 119 Ambient Temp - 64 Delta T Reading -18 Contactor Resistance Reading - No Issues Low Voltage Wiring Check No Issues Capacitor Reading 40/[email protected]/4.8 Clean Out Electrical Compartment Cleaned Refrigeration Line Check - Low Side Insulation Well Insulated Service Valve Cap No Issues Amp Draw On Compressor [email protected] Amp Draw On Condenser Fan [email protected] Lock Rotor Amps - [email protected] Check Filter/Replace Air Filter Looks Good Clean Drain No Issues Test Blower Motor No Issues
Nick , S. Carol Stream , IL
06-10-2022