Are you looking for gas furnace maintenance in Barrington, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Barrington, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Barrington, IL

Get Your Quote Today

Furnace Report • Inducer Amps MNF/ - Test/0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring Wiring Is All Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Liz , M. Barrington , IL
10-28-2022
Furnace Report • Inducer Amps MNF/ - Test/No Inducer • Clean Flame Sensor No Flame Sensor • Blower Motor Capacitor MNF/ - Test/[email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines No Pressure Switches • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good • Check Ignitor No Issues • Check/replace The Filter Filters Are Clean • Test Gas Shut Off No Issue • Test Thermostat For Proper Operation Thermostat Turns On Call No Jesus
Ross , M. Barrington , IL
10-28-2022
Rt Furnace Report: Furnace Report • Inducer Amps MNF/ - Test/0.8A • Clean Flame Sensor • Blower Motor Capacitor MNF/ - Test/ [email protected] • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Recommend Replacing Filter/dirty • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Ross, M. Barrington, IL
10-28-2022
Furnace Report: Furnace Report 1st Floor • Inducer Amps MNF/.65 - Test/.54 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Recommended Replacing • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Urnace Report: Furnace Report 2nd Floor • Inducer Amps MNF/ .65- Test/.53 • Clean Flame Sensor Cleaned Sensor Dirty • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Bob , M. Barrington , IL
10-15-2022
Furnace Report: Furnace Report • Inducer Amps MNF/1.0 - Test/.60 • Clean Flame Sensor Cleaned Sensor • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues Furnace Report • Inducer Amps MNF/1.0 - Test/ • Clean Flame Sensor Cleaned Sensor 3.4 • Blower Motor Capacitor MNF/ - Test/ NA • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orifices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace The Filter Replaced Air Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Charles, C. Barrington, IL
09-23-2022
Downstairs Furnace- Furnace Operations Are Good, Motors Working In Amp RAte Range. Cleaned Up Motor Housing, Flame Sensor, Burner Assembly, & Interior Of The Furnace. Blinking Light On Humidifier Was Due To Needing Maintenance & Changing Water Panel. Took Care Of Humidifier Maintenance For The Downstairs Furnace Upstairs Furnace- Operations Are Good. Motors Working In Amp RAte Range. Cleaned Up Motor Housing, Flame Sensor, Burner Assembly, & Interior Of The Furnace. Also Took Care Of The Humidifier Maintenance On The Upstairs Furnace. Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Charles, C. Barrington, IL
10-08-2021
Upon Arrival, Furnace Operations Are At A Good Working Amp Rate. Cleaned Up Motors & Burner Assembly. Offered Humidifier Service & Customer Accepted. Furnace Manufactured In November 2019. The Current Filter Is Still Good, A New Filter Left On The Side Of The Furnace Fall Preventive Maintenance Trip 1 Spring Preventive Maintenance Trip ALL MEMBERS Receive: - Priority Service - 10% Member Discounts - Safer Homes - More Efficient Equipment - Great Value - Special Offers - Home Service Updates - Energy Savings- Investment Protection - Peace Of Mind Heating Season - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Airflow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Cooling Season: - Check Refrigeration Pressures - Test Safety Controls - Measure For Correct Airflow - Tighten Electrical Connections - Measure Volts/amps On Motors - Clean Outdoor Condenser Coil - Clean Condensate Drains - Measure Temperature Difference - Test Cycle Unit - Change Filter Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Liz , M. Barrington , IL
10-05-2021
Upon Arrival, Furnace Interior Really Dirty, Furnace Manufactured In 11/2017. Vent & Blower Motor Working In Proper Amp Range . Filter Was Changed Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Ross, M. Barrington, IL
09-28-2021