If your gas furnace in Aurora, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Aurora, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Aurora, IL

We provide gas furnace repair in Aurora, IL

Get Your Quote Today

Screw Too Tight Changed Her Air Filter For Her
Patricia , B. Aurora, IL
04-07-2022
Upon Arrival Found Pressure Switch Not Closing Due To Obstruction In The Inducer Motor Port Cleared Port System Fired Up No Other Issues Recommended Preventive Maintenance.
Mike, U. Aurora, IL
03-25-2022
Furnace Report: Furnace Report • Inducer [email protected] • Clean Flame Sensor Cleaned Sensor • Inspect Blower Motor No Issues • Inspect Wiring No Issues • Inspect Burner No Rust • Inspect Orfices For Blockage Cleared All Ports • Carbon Monoxide Test 0ppm Found • Inspect Chimney No Issues • Inspect Pressure Switch Lines No Issues • Test Sequence Of Operation No Issues • Inspect Heat Exchanger No Issues • Check Ignitor No Issues • Check/replace Filter Air Filter Looks Good • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation No Issues
Alan , B. Aurora, IL
01-21-2022
Discovered Breaker Shut Off
Wilda , K. Aurora, IL
11-24-2021
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter Humidifier Maintenance: Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Prakash, K. Aurora, IL
11-05-2021
Weil McLain 378
No Heat Diagnosis. Checked Pressure Switches Checked Roll Outs Found Locked Draft Inducer Motor. Part Of Assembly Weil Mclain Boiler Replaced Inducer Motor Assembly Test Sequence Of Operation Start Up And Verify Burner.
Precision , I. Aurora , IL
12-10-2019
No Heat Upon Arrival. Replaced Faulty Igniter With Original Equipment Manufacturer's Part.