Gas Furnace Maintenance

Gas Furnace Maintenance

Are you looking for gas furnace maintenance in Addison, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Addison, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Addison, IL

Get Your Quote Today


Laurel , B. Addison , IL
02-06-2023
Furnace Report • Inducer Amps MNF/ - Test/2.0A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues. Clean Blue Flame No Cracks • Check Ignitor Ignitor Is All Good • Check/replace The Filter Recommend Replacing Filter • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Janet , B. Addison, IL
11-03-2022
Annual Furnace Preventative Maintenance: Your Fall Preventative Maintenance Includes - Clean Burner Assembly - Clean Flame Sensor - Inspect Heat Exchanger - Check Igniter - Test Safety Circuit - Carbon Monoxide Test - Check Sequence Operations - Inspect Blower Motor And Cage - Measure For Correct Air Flow - Tighten Electrical Connections - Measure Volts/amps On Motors - Change Filter
Jeff , W. Addison , IL
11-05-2021
Deep Coil Cleaning: Deep Cleaning Of Evaporator Coil Dissemble Coil Cabinet For Access To Evaporator Clean All Accessible Coil Fins And End Loops Coil/fin Brush All Aluminum/copper Coil Surfaces Clean Drain Pan Of All Debris Clear Condensate Lines Of Any Sludge + Does Not Include Cutting Of Refrigeration Piping For Access. An Additional Charge Will Be Added For Reclaiming, Evac, Startup. Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 200 Low Pressure - 70 Ambient Temp - 79 Delta T Reading -20 Contactor Resistance Reading -18 Low Voltage Wiring Check Capacitor Reading 35/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor -11.3 Amp Draw On Condenser Fan -1.26 Check Filter/Replace Clean Drain Test Blower Motor Service: Boiler Report • Draft Damper Operational • Verify Circulation Motor Operational • Inspect Wiring • Inspect Burner • Test Gas Valve • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Test Sequence Of Operation • Inspect Heat Exchanger • Test Spark Ignitor • Test Gas Shut Off • Test Thermostat For Proper Operation
Janet , B. Addison, IL
10-04-2021
• Inducer MNF 3.7/Test 2.2 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation • Clean 3/4 Drain Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Annual A/C Preventative Maintenance: Clean And Check Outdoor Condenser High Pressure - 200 Low Pressure - 70 Ambient Temp - 70 Delta T Reading -20 Contactor Resistance Reading - Low Voltage Wiring Check Capacitor Reading 44.9/5 Clean Out Electrical Compartment Refrigeration Line Check - Low Side Insulation Service Valve Cap Amp Draw On Compressor - 11.0 Amp Draw On Condenser Fan -1.2
Janet , B. Addison, IL
10-04-2021

Brian's Heatingstarstarstarstarstar4.6 / 5

5 stars
45
4 stars
0
3 stars
0
2 stars
1
1 stars
0

49 Total Reviews /files//brians-logo.png630-509-8310$847 Weyrauch St. , West Chicago IL

©Red Barn Media Group 2024