Upon Arrival, Furnace Motors In Good Working Condition. Cleaned Up Interior Of Furnace, Motor, Flame Sensor, Burner Assembly . Humidifier Working & Changed Hum Filter.
AC- Is Working In Good Operations, Motors Are In Good Amp Operations, Switches Are Good . Charge Is Good. Ac Manufactured In 1998
MP HUM Humidifier Maintenance:
Humidifier Maintenance And Cleaning
Disassemble And Inspect Aprilaire Humidifier
-Clean Drain Assembly
-Clean Distribution Tray
-Clean Water Feed Tube
-Verify Water Flow, Clean Orifice
-Clean Or Replace Drain Tube As Needed
-Verify 24v Control Operation
-Replace Media Filter
Set Manual Controls @ 35% For Winter Opperaion.
Verify Automatic Control Set In WiFi Stat
Annual Furnace Preventative Maintenance:
Your Fall Preventative Maintenance Includes
- Clean Burner Assembly
- Clean Flame Sensor
- Inspect Heat Exchanger
- Check Igniter
- Test Safety Circuit
- Carbon Monoxide Test
- Check Sequence Operations
- Inspect Blower Motor And Cage
- Measure For Correct Air Flow
- Tighten Electrical Connections
- Measure Volts/amps On Motors
- Change Filter
Annual A/C Preventative Maintenance:
Annual A/C Preventative Maintenance:
Clean And Check Outdoor Condenser
High Pressure - 178
Low Pressure - 68
Ambient Temp - 80
Delta T Reading -19
Contactor Resistance Reading -18
Low Voltage Wiring Check
Capacitor Reading 40/5
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation
Service Valve Cap
Amp Draw On Compressor -9.4
Amp Draw On Condenser Fan -.7
Check Filter/Replace
Clean Drain
Test Blower Motor