AC Cooling And Air Conditioning Systems Winfield, Illinois

At Brian's Heating, we install and service all brands of central air conditioning and cooling systems in Winfield, IL. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Winfield, IL.

Let us help you decide how best to solve your air conditioning needs today.

Get Your Quote Today



Brian's Heating AC Cooling And Air Conditioning Systems Winfield, Illinois



Recent AC Cooling And Air Conditioning Systems Winfield, Illinois by Brian's Heating

Armstrong HVAC 4SCU13LE160P-5

Winfield, IL
09-01-2020

4SCU13LE160P-5
Diagnosis Upon Inspection Discovered Compressor Not Running Test Capacitor Manf Reading 35 Herm Terminal Reading 13.3 Recommend Replacement 1 35/5 MF Capacitor Install 1 New Start / Run Capacitor

Winfield, IL
07-31-2020

Lennox HS22-311

A/C Report Clean and Check Outdoor Condenser High Pressure - 175 Low Pressure - 75 Delta T Reading 20 Contractor Resistance Reading 0 Low Voltage Wiring Check Capacitor Reading - 36.65/4.07 Clean out Electrical Compartment Refrigeration Line Check - Low side Insulation Service Valve Cap Amp draw on Compressor - 10.11 Amp Draw on Condenser Fan - 1.01 Check filter/Replace Clean drain
Winfield, IL
06-12-2020

Comfortmaker NAC036A

Clean and Inspection A/C A/C Report Clean and Check Outdoor Condenser High Pressure - 115 Low Pressure - 230 Delta T Reading 20 Contractor Resistance Reading 0 Low Voltage Wiring Check Capacitor Reading - 47/4.98 Clean out Electrical Compartment Refrigeration Line Check - Low side Insulation Service Valve Cap Amp draw on Compressor - 7.49 Amp Draw on Condenser Fan .75 Check filter/Replace Clean drain Clean and inspect air conditioner Clean condenser coil Check all electrical connections and wiring Check High side and Low side pressures Check refrigerant levels. Check Temperature difference Replace furnace filter
Winfield, IL
06-12-2020

Armstrong HVAC 4SCU13LE130P-5

AC Tune Up AC Clean AC Report Clean & check
Winfield, IL
06-12-2020

Carrier CD3AXA024000AAAAcoil

Replace indoor coil Replace Carrier cased coil with TXV CNPVP2414ALAAAAA 2613X21268 Pump down and save 410A refrigerant Cut out coil and replace with OEM Nitrogen sweep and braze in new coil Nitrogen pressure test Evacuate system Recharge and top off refrigerant Replace drain connections A/C Report
Winfield, IL
06-12-2020

CD3AXA024000AAAAcoil
Annual Cleaning And Inspection Of 2 Furnaces

Winfield, IL
09-13-2019

CD3AXA024000AAAAcoil
A/C Unit Was Not Working On Arrival. Found Drain Pan Was Filled With Water. Repaired Damaged Low Voltage Wiring Outside At Condenser.

Winfield, IL
07-30-2019

CD3AXA024000AAAAcoil
No Cooling On Arrival. Replaced Blown 45/5 Capacitor With A New Dual 45/5 Capacitor.

Winfield, IL
07-30-2019

CD3AXA024000AAAAcoil
"No Cooling" On Arrival. Found A Faulty Capacitor And A Blown Fuse. Tested Refrigerant Levels And Replaced Capacitor And Fuse. Restored Cooling Capabilities.

Winfield, IL
06-25-2019

CD3AXA024000AAAAcoil
Annual Cleaning And Inspection Of Air Conditioner

Winfield, IL
06-14-2019

CD3AXA024000AAAAcoil
Annual Air Conditioner Clean And Inspection For 2 Units

Winfield, IL
06-14-2019

CD3AXA024000AAAAcoil
Leaking Condenser - Added 3 Lbs Of 410-a And Injected Leak Stop.

Winfield, IL
06-05-2019

CD3AXA024000AAAAcoil
Annual Cleaning And Inspection Of Air Conditioner

Winfield, IL
04-26-2019

CD3AXA024000AAAAcoil
Replaced Burned Out Motherboard With New OEM Board

Winfield, IL
04-24-2019

CD3AXA024000AAAAcoil
Repaired Low And High Voltage Wiring Due To Mouse Damage.

Winfield, IL
04-22-2019

CD3AXA024000AAAAcoil
"No Heat" On Arrival. Restored Heat

Winfield, IL
04-22-2019

CD3AXA024000AAAAcoil
No Cooling On Air Conditioner. Installed New Honeywell Pro 3000 Thermostat. Added 2lbs Of R-22

Winfield, IL
04-17-2019

CD3AXA024000AAAAcoil
Installed New Humidifier

Winfield, IL
03-26-2019

CD3AXA024000AAAAcoil
Replaced "blown" Capacitor

Winfield, IL
03-22-2019

starstarstarstarstar
5 Star Rating
CD3AXA024000AAAAcoil
Annual AC Maintenance & Tune-UP

Winfield, IL
05-24-2018