Air Conditioning Service, Repair And Installation Wheaton, Illinois
Upon Arrival Troubleshooted Ac Unit And Discovered Condenser Fan Motor Not Working. Ohms Reading Was Off But Capacitor Was Good. Replaced Condenser Fan Motor.
Wheaton, IL
09-23-2022
Air Conditioning Service, Repair And Installation Wheaton, Illinois
Upon Arrival. Condenser Was Not Turning On At All. Discovered Bad Contactor And Blown Wires From Compressor To Electric Panel.
Wheaton, IL
08-06-2022
Air Conditioning Service, Repair And Installation Wheaton, Illinois
Upon Arrival Found Frozen Coil Have To Thaw Out System Recommended Preventive Maintenance Agreement And Dye Kit Customer Agreed Added 2lbs Of R410 To Balance System Ac Now Cooling Properly We Need To Come Back And Do A Dye Search.
Wheaton, IL
05-27-2022
Air Conditioning Service, Repair And Installation Wheaton, Illinois
Did Not Charge Customer Due To We Were Supposed To Come Back To Check For Dye And It Was Never Scheduled
Upon Arrival Customer Explained No A/c. I Turned The System On And
Discovered Outdoor Unit Not Operational. Test Incoming Power To Discover No Power. I Found Breaker Box And Discovered Breaker Off. I Turned The Breaker Back On And Tested The Pressures.
Also Discovered Filter Clogged Causing Unit To Possibly Freeze
Wheaton, IL
10-07-2021
Air Conditioning Service, Repair And Installation Wheaton, Illinois
PTEST1 Pressure Test:
Test For Larger Refrigerant Leaks
We Will Pump Down And Save Any Refrigerant Possible Into The Condenser.
Pressurize The Lineset And Indoor Coil With 400 PSI Of Nitrogen And Refrigerant Trace Gas.
Electronic Leaks Detect All Lines, End Loops, All Accessible Fittings, Coils, Manifolds, Service Ports.
Soap Test All Accessible End Loops, Joints, And Coils
+ Once Leaks Or Leaks Are Found We Will Present Repair Options With Pricing.
Wheaton, IL
10-01-2021
Air Conditioning Service, Repair And Installation Wheaton, Illinois
Explained To Customer The Filter Blockage Was Causing Air Flow Issues. Followed Up With The Blower Cfm Being 200 Over Required Specs
Wheaton, IL
09-22-2021
Air Conditioning Service, Repair And Installation Wheaton, Illinois
Upon Arrival Customer Turned System On, The Fan And Compressor Tried To Start But Could Not. I Diagnosed Faulty Capacitor
Wheaton, IL
09-21-2021
Air Conditioning Service, Repair And Installation Wheaton, Illinois
Includes 1 Hour Of Standard Diagnosis On One HVAC System.
Each Additional System Diagnosis Will Have An Additional Fee.
Customer Reported Issue: Hard Start On Start Up
Recommended Repairs: Replace Capacitor
200 / 94471 TURBO 200 2.5 MFD - 67.5 MFD:
Universal Run & Start Capacitor Replacement.
Universal HardStart Replacement. One
WHEATON, IL
07-01-2021
Armstrong HVAC
4SCU16LE160P-4
TURBO 200 2.5 MFD - 67.5 MFD:
Universal Run & Start Capacitor Replacement.
Universal HardStart Replacement. One
WHEATON,
IL
06-30-2021