Are you looking for gas furnace maintenance in Deer Park, IL ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Deer Park, IL. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Deer Park, IL

Get Your Quote Today

Furnace Report Furnace 2nd Floor Main Level • Inducer Amps MNF/ - Test/0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report Furnace 1st Floor Basement • Inducer Amps MNF/ - Test/4.4A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/N/A Relay • Inspect Wiring High Limit Was Disconnected. Other Than That All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockage No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger No Issues, No Cracks Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues Furnace Report Furnace Upstairs 3rd Floor • Inducer Amps MNF/ - Test/ 0.5A • Clean Flame Sensor Cleaned Flame Sensor • Blower Motor Capacitor MNF/ - Test/ N/A Relay • Inspect Wiring All Wiring Is Good • Inspect Burner Cleaned And Cleared Burners • Inspect Orifices For Blockages No Blockages • Carbon Monoxide Test No Issues • Inspect Chimney Chimney/exhaust Is Venting Properly • Inspect Pressure Switch Lines Cleared Pressure Switch Lines • Test Sequence Of Operation Sequence Of Operations Is Good And In Order • Inspect Heat Exchanger Heat Exchanger Is Good No Issues. Clean Flame • Check Ignitor Ignitor Is All Good • Check/replace The Filter Filter Is Clean • Test Gas Shut Off No Issues • Test Thermostat For Proper Operation Thermostat Turns On Call No Issues
Joe , T. Deer Park , IL
10-28-2022
Furnace Report • Inducer Amps MNF/1.0 - Test/.72 • Clean Flame Sensor • Inspect Blower Motor • Inspect Wiring • Inspect Burner • Inspect Orfices For Blockage • Carbon Monoxide Test • Inspect Chimney • Inspect Pressure Switch Lines • Test Sequence Of Operation • Inspect Heat Exchanger • Check Ignitor • Check/replace Filter • Test Gas Shut Off • Test Thermostat For Proper Operation Humidifier Maintenance And Cleaning Disassemble And Inspect Aprilaire Humidifier -Clean Drain Assembly -Clean Distribution Tray -Clean Water Feed Tube -Verify Water Flow, Clean Orifice -Clean Or Replace Drain Tube As Needed -Verify 24v Control Operation -Replace Media Filter Set Manual Controls @ 35% For Winter Opperaion. Verify Automatic Control Set In WiFi Stat
Joe & Stacy, T. Deer Park, IL
12-01-2021