Air Conditioning Maintenance Carol Stream, Illinois
Completed Ac Clean And Check. Upon Arrival, Noticed Air Filter Needed To Replaced And Homeowner Approved To Get One Off The Truck. Inspected Blower Department And Continued Inspection To Outdoor Unit. Found Everything To Be Between Manufacturing Specifications. Recommended Renewing Agreement But Homeowner Will Think About And Call Us In The Future To Renew Agreement.
Carol Stream, IL
04-12-2024
Air Conditioning Maintenance Carol Stream, Illinois
Upon Arrival, Homeowner Mentioned How Upstairs Gets Warm And Explained That Eco Bee Have A Fan Circulation Option Or Her Current Thermostat Can Have Fan On All The Time But Cause Her Motor To Run More. This Will Help With Bring The Upstairs Temp Down. Continued Inspection To Indoor Unit And Found Filter Dirty And Took Out Of System And Recommended Replacing Filter Asap. Blower Wheel Is Dirty And Recommended Blower Cleaning But Homeowner Declined At This Time. Continued Inspection Outdoor And Everything Tested Between Manufacturing Specifications. Please Reference Tune Up Form.
End Of Visit We Spoke About UV Light And It’s Benefits As She Suffers From Allergies And This Can Help Keep Air Clean Inside The House. Especially After They Clean Their Ducts. She Requested To Leave Estimate For All This. Which Is Attached. This Visit Was Part Of Membership Agreement.
Carol Stream, IL
04-12-2024
Air Conditioning Maintenance Carol Stream, Illinois
Completed Ac Tune Up. Inspected Blower Department And TD Of 19 And Continued Inspection Outdoor Unit Mechanical Components And Ac Refrigerant Levels Are All To Specifications. Cleaned Condenser Coil. Please Reference Tune Up Form For Details. Renewed Agreement During Visit.
Carol Stream, IL
04-09-2024
Air Conditioning Maintenance Carol Stream, IllinoisA/C Report:
A/C Report
Clean And Check Outdoor Condenser
High Pressure - 260
Low Pressure - 121
Ambient Temp - 74
Delta T Reading -19
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check
Capacitor Reading 45/[email protected]/4.8
Clean Out Electrical Compartment
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap In Place
Amp Draw On Compressor [email protected]
Amp Draw On Condenser Fan [email protected]
Lock Rotor Amps - [email protected] Recommended Hard Start Kit 61.4
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
Carol Stream, IL09-23-2022
Air Conditioning Maintenance Carol Stream, IllinoisA/C Report
Clean And Check Outdoor Condenser
High Pressure - 280
Low Pressure - 111
Ambient Temp - 78
Delta T Reading -19
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 70/[email protected]/4.9
Clean Out Electrical Compartment Clean
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap In Place
Amp Draw On Compressor [email protected]
Amp Draw On Condenser Fan [email protected]
Lock Rotor Amps - 134@141 Recommended Hard Start Kit 98.5
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
Carol Stream, IL07-11-2022
Air Conditioning Maintenance Carol Stream, IllinoisA/C Report R22
Clean And Check Outdoor Condenser
High Pressure - 180
Low Pressure - 65
Ambient Temp - 80
Delta T Reading -19
Contactor Resistance Reading - No Issues
Low Voltage Wiring Check No Issues
Capacitor Reading 45/[email protected]/4.9 Recommended Cap
Clean Out Electrical Compartment Cleaned Spider Webs
Refrigeration Line Check - Low Side Insulation Well Insulated
Service Valve Cap No Issues
Amp Draw On Compressor -?10.3
Amp Draw On Condenser Fan [email protected]
Lock Rotor Amps - ? Now At 85.5
Check Filter/Replace Air Filter Looks Good
Clean Drain No Issues
Test Blower Motor No Issues
Carol Stream, IL06-11-2022